Copper Water Pipe Through Concrete Floor

It is acceptable to run a copper water tube through a concrete floor or wall, provided that allowance is made for the lateral thermal expansion and movement of the tube and protection of the tube from abrasion. This can be done by insulating the tube where it passes through the wall or by wrapping the tube with an approved tape (to avoid abrasion) and installing it through a sleeve. Please refer to your local plumbing code for specific requirements regarding the protection of pipes and tubes passing through concrete and masonry floors and walls. Both of the protection methods outlined above and the requirements listed in most plumbing codes are simply to protect the copper tube from the fatigue and wear caused by thermal expansion and movement. These protective measures are in no way dictated by the interaction of the concrete and the copper tube.